Welcome to A2Z Ozone! We manufacture and sell high-quality ozone generators using Corona Discharge Technology for residential and commercial applications. Below are answers to our most common questions. For technical questions not covered here, please contact us at [email protected] or call +1 502 499 4977 (option 1).

Getting Started

A2Z Ozone generators are designed for a wide range of applications including air treatment, water purification, odor elimination, food storage, pool treatment, and more. We have an option for almost any ozone application you need.

How-To Blog: Visit our How-To Blog https://a2zozone.com/blogs/for articles on using products, removing odors, cleaning vegetables, treating water, and more.

Video: Check out our YouTube channel: https://www.youtube.com/@atozozone for visual demonstrations and helpful references.

Odor Guide: See our Odor Type Page: https://a2zozone.com/a-complete-guide-to-odor-removal/ for a comprehensive guide on how ozone can help eliminate specific odors.

Products & Specifications

Product-Specific Questions

The Aqua-8 produces 800 mg per hour. Each 20-minute run produces 1/3 of 800 mg (approximately 267 mg) when using an oxygen feed. With ambient air only, it produces 2.5 mg/L airflow. The internal air pump airflow is approximately 1 LPM (liter per minute).

Lower flow rates result in higher ozone concentration. Higher oxygen flow rates dilute the ozone, reducing the concentration levels but hire total ozone output.

The Air-3500 unit has a power consumption of 95 watts.

We recommend running your unit for 2 minutes for an 8 oz glass of water. This amount of time is generally good for most water types.

For a gallon of filtered water using ambient air, we recommend running the MP3000 for approximately 5 minutes.

Replace stones and tubing as needed or every 6 months. You can clean the fan screen as often as necessary.

SP-Series, MP-Series, S-Series, and Z-Series require a 5/16” check valve. The Aqua-Series requires a 1/4″ check valve.

For a 1″ pipe, use a 1/2″ venturi injector. We recommend ½ size smaller from your piping to ensure adequate pressure.

Technology Questions

The ceramic plate in our ozone generators produces Corona Discharge—they’re the same technology.

The FDA does not approve specific ozone generators. While the EPA regulates ozone generators (we display our EPA number on our website and units), regulation compliance is different from approval. Any company claiming FDA or EPA approval is misleading.

The main difference is in the output and the method of production:

  • Corona discharge uses electricity and produces high ozone levels
  • UV uses ultraviolet light and produces low ozone levels

Corona discharge produces significantly more ozone—often 10 to 100 times more than UV systems.

Corona discharge is better because it provides:

  • Higher ozone concentration
  • More effective oxidation
  • Better scalability for larger systems

If using ambient air without an oxygen source, they can produce nitrogen oxides (NOx).
Using an oxygen concentrator or dry air system greatly reduces this.

UV generators are often considered simpler to use. They produce lower output, therefore, less risk of overexposure and they are free of nitrogen oxides.

However, they are not suitable for high-demand applications. Operating with ozone in any form requires caution. Corona discharge units require more caution. That’s why A2Z Ozone offers an Ozone Destructor and support to ensure you get the safest and best possible experience.

Corona discharge: Yes, humidity reduces output significantly. That is why we recommend using an oxygen generator or an air dryer to protect your machine and increase clean, pure ozone production.

UV: No, it does not affect ozone output; it remains stable, but the amount of ozone produced is smaller.

UV lamps: Typically last 4,000–10,000 hours.

CD plates/electrodes: Typically last 3,000–7,000 hours. We partner with you. With your fine care and our expert service department, your unit can last much longer.

Only for small-scale or light-duty applications.
UV cannot replace corona discharge where high ozone levels are required.

Choose Corona Discharge for:

  • Hydroponics
  • Water treatment
  • Commercial/industrial use
  • Heavy-duty use

Choose UV for:

  • Small air purification
  • Odor control
  • Light-duty use

Some customers use UV for a supplement to corona discharge for certain heavy applications.

Yes — when properly dosed and dissolved in the nutrient solution or irrigation water, ozone breaks down into oxygen before it reaches plant tissue. Peer-reviewed studies confirm no detectable residue on produce at standard treatment doses. See our article, “How Ozone Supercharges Hydroponics with the Z-Series Commercial Ozone Generator” for more information.

Ozone treats the water, not the root zone directly. If you are running a biological system, apply ozone upstream before the nutrient reservoir, not at the roots. The Z-Series is designed for recirculating systems where controlled contact time protects your biology while eliminating pathogens in solution.

Both are oxidizing agents, but ozone (O₃) is roughly 1.5× more powerful as an oxidizer and leaves no chemical residue. It breaks down into pure oxygen (O₂). Hydrogen peroxide (H₂O₂) requires precise dosing to avoid root damage and leaves residual peroxide in solution.

Yes. Deep water culture (DWC) systems benefit significantly from ozone because the recirculating water is in continuous contact with roots. Introduce ozone at the reservoir inlet, not directly at root level, and use an appropriately sized contact tank or venturi injector for proper dissolution.

In most applications, no. Ozone reacts quickly and naturally decomposes back into oxygen. By the next day, essentially no dissolved ozone remains.

Not always. Effective contact time depends on ozone concentration, water quality, temperature, and the treatment objective. Proper system design balances all of these factors.

Yes. Dissolved ozone can be measured using specialized test kits, probes, or colorimetric methods designed specifically for ozone.

Changes in water temperature, contaminant levels, pH, mixing efficiency, and flow rate can all affect how much dissolved ozone remains in the water.

One of the most common misconceptions about ozone treatment is that it significantly changes the pH of water.

In most water treatment applications, ozone has little or no lasting effect on pH.

Unlike chemical disinfectants such as chlorine or acids and bases, ozone reacts by oxidation rather than by permanently adding acidic or alkaline compounds to the water. As ozone decomposes, it simply reverts back to ordinary oxygen (O₂).

Some water systems may experience a small, temporary shift in pH during treatment, particularly if ozone is oxidizing dissolved metals or other compounds. However, these changes are generally caused by the chemical reactions taking place in the water rather than by the ozone itself.

For hydroponics, aquaculture, food processing, and most industrial water systems, pH should still be monitored and adjusted as needed because factors such as nutrient additions, biological activity, and dissolved minerals typically have a much greater influence on pH than ozone treatment.

Bottom line: Ozone is an excellent oxidizer, but it is not a practical method for raising or lowering pH.

Ozone doesn’t simply hide contaminants—it changes them through oxidation.

When dissolved ozone encounters contaminants in the water, it reacts almost immediately. Depending on the contaminant, ozone can:

Break down complex organic molecules into smaller compounds.
Oxidize dissolved iron and manganese so they can be removed by filtration.
Oxidize hydrogen sulfide, reducing sulfur-related odors.
Damage the cell walls or outer structures of microorganisms, preventing them from functioning or reproducing.
Reduce color, taste, and odor compounds caused by naturally occurring organic matter.

Unlike traditional filters, ozone does not remove contaminants from the water by itself. Instead, it changes their chemical structure, making them easier to separate, degrade, or filter.

This is why ozone is often used together with mechanical filtration rather than as a replacement for it.

Ozone is one of the most effective disinfectants used in water treatment.

When microorganisms come into contact with dissolved ozone, oxidation damages essential cellular components.

For bacteria, ozone attacks the cell membrane, allowing cellular contents to leak out.

For viruses, ozone oxidizes proteins and genetic material needed for infection, preventing the virus from reproducing.

Because ozone reacts so quickly, effective microbial treatment depends on having:

  • Sufficient dissolved ozone concentration
  • Adequate contact time
  • Proper mixing
  • Water that is reasonably free of suspended solids

If microorganisms are shielded inside particles of dirt or organic debris, ozone may not reach them effectively.

This is another reason why good filtration significantly improves ozone performance.

Many people assume ozone can replace a filtration system.

In reality, ozone and filtration are complementary technologies. Ozone definitely does not have to work as hard with filtration present.

Large suspended particles, leaves, algae clumps, sediment, and other debris consume ozone that would otherwise be available to treat dissolved contaminants and microorganisms.

Mechanical filtration removes these larger materials before ozonation, allowing the ozone to focus on contaminants that filters cannot easily remove.

A typical treatment sequence is:

  • Mechanical filtration removes suspended solids and debris.
  • Ozone injection oxidizes dissolved contaminants and microorganisms.
  • Contact time allows oxidation reactions to occur.
  • Post-filtration removes oxidized particles that have formed during treatment, when applicable.

This combination is often more effective and economical than relying on either technology alone.

Testing & Measurement

We offer two types of testing equipment in our accessories section:

Visit our Monitors and Testing

https://a2zozone.com/product-category/monitors-and-testing/ How many gallons can my unit handle?

It depends on how much water, water quality, and factors such as temperature and humidity. The ozone concentration is also a factor.

We offer calibration services at our facility using specialized equipment. You can either:

For calibration requests, please call +1 502 499 4977.
**First calibration is free with all lab units.

Water & Safety

Yes. Some people drink reverse osmosis water. When ozonating water without an oxygen source, small amounts of nitrous oxide may be produced as a byproduct. This is a normal occurrence.

Water ozone treatment can extend food shelf life by at least one week.

As we are not medical professionals, we cannot provide advice on how long ozone takes to kill pathogens or on specific health-related applications. Contact your doctor or practitioner for this advice.

Ordering & Support

Need a user manual for an industrial, lab, or commercial unit?
Please provide:

  • The unit model
  • Your full name
  • Your best contact email address

We will send the user manual to you via email.

Manuals for Aqua-Series, MP-Series, SP-Series, and Aquatic Spa units are available on our website:

https://a2zozone.com/product-manuals/

Current inventory status varies. Check our website for current product availability:

See our Refund and Return policy page:

https://a2zozone.com/refund_returns/

Contact our sales department:

Senior or Military Discounts?
Contact our sales department for available coupon codes:

Check for ongoing sales and special deals on our Special Deals Page.

https://a2zozone.com/a2z-ozones-current-special-deals/

Business Partnerships

If you’re interested in becoming a reseller or partner, please reach out to our sales department:

Still Have Questions?

For technical questions, product recommendations, or anything not covered here, please contact us: